4101 Power Test System Specifications
|
|||||||||||||||||||
![]() |
|||||||||||||||||||
![]() |
|||||||||||||||||||
|
APPLICATION
The 4041 three-phase system, specifically designed for the power utilities industry, is used in power systems modeling, and testing of protective relays and panels, transformers, CT's and VT's. FEATURES |
|||||||||||||||||||
|
INDIVIDUAL AMPLIFIER SPECIFICATIONS
|
|||||||||||||||||||
|
7780RLY
|
|||||||||||||||||||
|
LV3620
|
|||||||||||||||||||
|
INDICATORS AND CONTROLS
> Front panel LEDs indicate on, standby, and fault conditions. > Front panel run/reset switch and ready/standby switch. > Overload, over voltage, and over temperature indicators |
|||||||||||||||||||
|
INDICATORS AND CONTROLS
> Channel 1 and 2 Overload indicators > Power indicator > AC Power Switch |
|||||||||||||||||||
|
PERFORMANCE (One hour continuous ratings)
Max. Output Voltage 140 V pk Max. Output Current 180 A pk Output Load Constraints 0.25 ohms, 50 microhenries Output Impedance: >250 ohms at 60 Hz DC Output Offset Current <10.0 milliamps pk (input shorted) CMRR -70 dB min, 40 to 600Hz Differential Phase Error <0.1 degree at 60 Hz Residual Noise <2.5 milliamps pk (40Hz to 600Hz) Gain 40 A/V plus or minus 0.2% Frequency Response DC to 10 kHz, into 0.25 ohms THD + Noise <0.10% at 600 Hz, full output power |
|||||||||||||||||||
|
PERFORMANCE (One hour continuous ratings)
Max. Output Voltage 150 Vpk/ch, 300Vpk mono Max. Output Current 7.25 Apk/ch Output Load Constraints 24 ohm min, 0 to 90 degrees Output Impedance: <10 milliohms in series with less than 2 microhenries DC Output Offset Voltage <10.0 millivolts pk (input shorted) CMRR -70 dB min, 40 to 600Hz Differential Phase Error <0.1 degree at 60 Hz Residual Noise <10 millivolts pk (40Hz to 600Hz) Gain 40 V/V plus or minus 0.2% Frequency Response DC to 20 kHz THD + Noise <0.10% at 600 Hz, full output power |
|||||||||||||||||||
|
PHYSICAL CHARACTERISTICS
Dimensions: Single-bay: 61 in (155 cm) high X 23.1 in (58.7 cm) wide X 36.3 in (92.2 cm) deep (Includes casters and anti-tip extenders Weight: Approximately 900 lbs (408 kg) for single-bay cabinet Operating Environment Ambient temperature: 50 to 99 degrees F (10 to 37 degrees C) Humidity: 10% to 70% non-condensing Altitude: -400 to 8000 ft (-120 to 2440 m) Magnetic Field: 200 gauss max. Color: Ash white standard ; custom colors available. SUPPORT |
|||||||||||||||||||
| Copyright AE Techron, Inc. 2007 Report site problems to the webmaster. | |||||||||||||||||||