7224 POWER AMPLIFIER
The World's First Cost-Effective DC - 300kHz Power Amplifier
Features
The 7224 power amplifier offers the power and features of larger industrial amplifiers in a new smaller 2U size that runs from single phase 120/230VAC. It features DC - 300 kHz bandwidth, controlled current or controlled voltage modes of operation and has a wide range of field configurable options.
The 7224 is typically used to create waveforms found in EMC standards like CS2009, DO-160, MIL STD 461, and as a gradient amplifier for very small bore, high-gain MRI and NMR systems. Optional "P" version offers precision control of output offset, DC drift and gain linearity.
- CONTROLLED VOLTAGE
- CONTROLLED CURRENT
- FREQUENCY DATA
- PHYSICAL CHARACTERISTICS
AC Specifications
High Voltage Mode |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| 16 | 158 | 10 | 158 | 10 | 158 | 10 | 112 | 7 | 112 | 7 | 774 |
| 8 | 154 | 19 | 136 | 16 | 136 | 16 | 96 | 12 | 96 | 12 | 1108 |
| 4 | 124 | 31 | 108 | 26 | 61 | 15 | 76 | 18 | 43 | 10 | 442 |
| 2 | 98 | 49 | |||||||||
Mid-Level Mode |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| 4 | 72 | 18 | 69 | 16 | 69 | 16 | 49 | 12 | 49 | 12 | 566 |
| 2 | 61 | 30 | 57 | 26 | 57 | 26 | 40 | 19 | 40 | 19 | 746 |
| 1 | 47 | 47 | 43 | 40 | 21 | 21 | 30 | 28 | 15 | 15 | 220 |
| 0.5 | 26 | 52 | |||||||||
High Current Mode |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| 1 | 29 | 29 | 29 | 29 | 21 | 21 | 21 | 21 | 420 | ||
| 0.75 | 26 | 34 | 26 | 34 | 18 | 24 | 18 | 24 | 442 | ||
| 0.5 | 23 | 45 | 23 | 45 | 16 | 32 | 16 | 32 | 511 | ||
| 0.25 | |||||||||||
Check back soon for updated product information





DC Specifications
| High Current | 5 Minutes |
1 Hour |
| Volts DC | Amps DC | Amps DC |
| 48.0 | 12 | 12 |
| 24.0 | 26 | 20 |
| 13.5 | 20 | 16 |
| 3.0* | 25 | 25 |
* A 120VAC only special configuration.
Display, Control, Status, I/O
Front Panel

LED Displays Indicate: Ready, Standby, Fault, Over Temp, Over Voltage, Overload
Soft Touch Switches for: Run, Stop, Reset
Gain Control, when enabled: Voltage gain adjustable from 20 to 0
On/Off Breaker

NEMA 5-20

CEE 7/7
Back Panel
Power Connection:
120VAC: 20A IEC Cable with NEMA 5-20
230VAC: 10A IEC Cable with CEE 7/7
Signal Output: +/Common/Sampled Common
Signal Input: User Selectable BNC or Barrier Strip, Balanced
Communication Capabilities
Current Monitor: +/- 1V / 6A +/- 1%
Voltage Monitor: +/- 1V / 20V +/- 1%
Input Signal Monitor: +/- 1V . 2V +/- 1%
Physical Characteristics
Chassis: The amplifier is designed for stand-alone or rack-mounted operation. The chassis is black aluminum with a powder-coat finish. The unit occupies two EIA 19-inch-wide units.
Weight: 41 lbs (18.6 kg), Shipping Weight: 51 lbs (23.2 kg)
AC Power: Single phase, 120VAC, 60 Hz, 20 Amp Service; 220-240 VAC, 50/60 Hz, 10 Amp model available
Cooling: Forced air cooling from front to back through removable filters
Dimensions: 19 in. x 22.75 in. x 3.5 in. (48.3 cm x 57.8 cm x 8.9 cm)
Copyright AE Techron, Inc. 2010 - Formerly Techron - MRI Mouse image courtesy of Aspect MRI - Report site problems to the webmaster.