1 Hour Continuous Power Rating
|
||||||
|
Load
|
Voltage
RMS |
Amps
RMS |
Watts
RMS |
Voltage
Peak |
Amps
Peak |
Watts
Peak |
|
None
|
140
|
200
|
||||
|
16
|
138
|
8.6
|
1190
|
195
|
12
|
2340
|
|
8
|
130
|
16.3
|
2112
|
183
|
23
|
4209
|
|
4
|
117
|
29.3
|
3422
|
165
|
41
|
6765
|
|
2
|
61
|
30.5
|
1860
|
86
|
43
|
3698
|
|
1
|
53
|
53
|
2809
|
75
|
75
|
5625
|
|
0.5
|
Not recommended
|
|||||
When you purchase an AE Techron amplifier, a full complement of technical and factory support personnel join your team. AE Techron inc. provides:
• Applications engineering for your technical questions and customized product needs.
• A one year limited warranty to protect your equipment investment.
• A fully equipped service center to keep your amplifier operating at original performance requirements.

Chassis
All aluminum construction designed for stand alone or rack mounted operation with black chassis.
The Amplifier occupies five EIA 19-inch-wide rack units.
Weight
103 lbs. (46.7 kg)
AC Power
Three phase, 208 volts, 47-60 Hz, 30 amperes ac service.
Cooling
Internal fans forced air, 250 cfm.
Dimensions
19 in. x 8.75 in. x 22.8 in. (48.3 cm x 31.1 cm x 57.9 cm)
|
40mS Pulse Power Rating
|
||||||
|
Load
|
Voltage
RMS |
Amps
RMS |
Watts
RMS |
Voltage
Peak |
Amps
Peak |
Watts
Peak |
|
None
|
142
|
208
|
||||
|
2
|
103.5
|
49
|
5072
|
150
|
123
|
18450
|
|
1.5
|
91
|
60.4
|
5496
|
134
|
90
|
12060
|
|
1
|
78.4
|
72
|
5645
|
116
|
105
|
12180
|
|
0.5
|
43
|
77
|
3311
|
66
|
112
|
7392
|
Frequency Response
DC – 30kHz +0.1 – 0.5dB
Phase Response
+/- 8.3 degrees (10Hz - 10kHz)
Unit to Unit Phase Error
+/- 0.1 degrees at 60Hz
Maximum continuous output power
3300 watts rms
Output offset current
Less than 10 milliamperes dc
Input
Balanced with ground: three terminal barrier block connector 20k ohm differential.
Unbalanced: BNC connector, 10k ohm single ended.
Gain
20 volts/volt (voltage mode)
20 amperes/volt (current mode)
Residual Noise
DC - 30kHz Less than 75 microvolts
DC - 100kHz Less than 1 millivolt
Slew Rate
41 volts per microsecond


• Front panel LEDs indicate ready, standby and fault conditions in output stage.
• Front panel display lists type of fault condition and gives suggested corrective action.
• Front panel soft touch switch to place amplifier in run or standby mode.
• Front Panel is user configurable for up to four simultaneous displays reporting one, two or all four of the following: Voltage Peak, Voltage RMS, Current Peak, and Current RMS.
• Over 12,000 watts peak for 40 milliseconds into a 1.5 ohm load.
• 40 mSec pulses of up to 72 amperes peak into a 1 ohm load.
• System output of 800 volts and 70 amperes maximum are possible with multiple, interconnected amplifiers.
• Frequency bandwidth of DC to 50kHz at rated power, DC to 100kHz at reduced power.
• Rugged chassis for stand-alone or rack mounted operation. No additional power supplies are required.
• Protection circuitry protects the AE Techron 7548 from input overloads, improper output connection (including shorted and improper loads), over-temperature, over-current, and supply voltages that are too high or low.
• Shipped ready to operate from 208 volt, three-phase AC mains. Operation from 380 or 415 volt AC mains are available on request
The Model 7548 is a part of expanding line of new precision linear amplifiers; it combines everything we have learned in over 40 years of building high power linear amplifiers.
The AE Techron 7548 Amplifier is a high powered unit designed to provide very low noise and fast slew rates. The 7548 can safely drive a wide range of resistive, inductive loads. Typical uses include signal amplifier for high gain gradient coils in magnetic resonance imaging systems or a power source
A single 7548 has an output capability of 100 amperes peak and 200 volts peak when driving typical