7548 POWER AMPLIFIER
Up to 100 Apeak, DC - 100kHz Amplifier for Pulse or Continuous Duty
Features
The 7548 power amplifier offers up to 100 Ap power, DC - 100 kHz bandwidth, controlled current or controlled voltage modes of Operation, in a compact 5U size. The 7548 works best with loads of 2 ohms or more. For greater voltage (up to 750Vp) or current, units can be combined in series or parallel.
Typically used as a gradient amplifier in small bore, high gain MRI systems of up to 100 Ap per axis and to reproduce waveforms found in EMC standards like MIL 704.
Optional "P" version offers precision control of output offset, DC drift and gain linearity.
- CONTROLLED VOLTAGE
- CONTROLLED CURRENT
- FREQUENCY DATA
- PHYSICAL CHARACTERISTICS
AC Specifications
Standard |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 20% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| open | 200 | 0 | 200 | 0 | 200 | 0 | 141 | 0 | 141 | 0 | 0 |
| 16 | 195 | 12 | 195 | 12 | 195 | 12 | 138 | 8 | 138 | 8 | 1170 |
| 8 | 183 | 23 | 183 | 23 | 183 | 23 | 129 | 16 | 129 | 16 | 2104 |
| 4 | 165 | 41 | 165 | 41 | 165 | 41 | 117 | 29 | 117 | 29 | 3381 |
| 2 | 150 | 75 | 86 | 43 | 0 | 0 | 61 | 30 | 1848 | ||
| 1.5 | 134 | 90 | |||||||||
| 1 | 116 | 105 | |||||||||
| 0.5 | 66 | 112 | |||||||||
Optional High-Current (HC) Version |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 20% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| 2 | 55 | 39 | 55 | 28 | 55 | 28 | 39 | 20 | 39 | 20 | 770 |
| 1 | 51 | 36 | 51 | 51 | 48 | 48 | 36 | 36 | 34 | 34 | 1152 |
| 0.5 | 26 | 52 | 26 | 52 | 26 | 52 | 18 | 37 | 18 | 37 | 676 |
Check back soon for updated product information



Indicators and Controls
Front Panel
LED Displays Indicate: Ready, Standby, and Fault Conditions in the output stage
LCD Display: Lists type of Fault Condition and gives suggested corrective action; User-configurable for up to four simultaneous displays reporting, one, two or all four of the following: Voltage Peak, Voltage RMS, Current Peak, and Current RMS
Soft Touch Switch: Places amplifier in Run or Standby mode
Back Panel
Signal Output: +/Common/Sampled Common
Signal Input: User Selectable BNC or Barrier Strip, Balanced
Communication Capabilities
Current Monitor: +/- 1V / 20A +/- 1%
Voltage Monitor: +/- 1V / 20V +/- 1%
Physical Characteristics
Chassis: Black, all-aluminum chassis is designed for stand-alone or rack-mounted operation. The unit occupies five EIA 19-inch-wide units.
Weight: 103 lbs (46.7 kg)
AC Power: Three phase, 208 VAC (+/-10%), 47-60 Hz, 30A AC service (400 VAC (+/-10%), 15A version available)
Cooling: Internal forced-air fans, 250 cfm.
Dimensions: 19 in. x 22.8 in. x 8.75 in. (48.3 cm x 57.9 cm x 22.25 cm)