7782HF POWER AMPLIFIER
Ideal for High-Current Applications like DO-160 Testing
Features
The 7782HF is an extended frequency verison of the 7782. The 7782HF is best suited for controlled voltage applications that require higher voltages between 50kHz - 100kHz. The 7782HF is ideal for situations like DO-160 testing that require high current from DC - 20kHz and DC - 150kHz power bandwidth.
- CONTROLLED VOLTAGE
- CONTROLLED CURRENT
- FREQUENCY DATA
- PHYSICAL CHARACTERISTICS
AC Specifications
Standard |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| open | 0 | 0 | 0 | 0 | 0 | ||||||
| 4 | 120 | 30 | 120 | 30 | 85 | 21 | 85 | 21 | 1799 | ||
| 2 | 120 | 60 | 115 | 58 | 85 | 42 | 81 | 41 | 3305 | ||
| 1 | 80 | 80 | 68 | 68 | 57 | 57 | 48 | 48 | 2311 | ||
| 0.5 | 46 | 92 | 44 | 88 | 33 | 65 | 31 | 62 | 1935 | ||
Optional High Current (HC) Version |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| 2 | 0 | 0 | 0 | 0 | 0 | ||||||
| 1 | 56 | 56 | 55 | 55 | 39 | 39 | 0 | 0 | 0 | ||
| 0.5 | 42 | 84 | 41 | 82 | 29 | 58 | 0 | 0 | 0 | ||
| 0.1 | 15 | 150 | |||||||||
Check back soon for updated product information

| 7782HF DC Power Over Time Summary | |||
| Time in Minutes | Impedance | Volts | Amps |
| 2 | 1 | 50 | 50 |
| 2 | 0.5 | 30 | 60 |
| 1.5 | 0.27 | 19 | 75 |
| 5 | 1 | 40 | 40 |
| 5 | 2 | 84 | 42 |
| Continuous | 2 | 42 | 21 |
Indicators and Controls
Front Panel
LED Displays Indicate: Power, Standby, High AC Mains, High Temperature, Signal Overload and Faulty Output Stage.
Slide Switches for: Run/Standby, LED Indicator Reset
Back Panel
Signal Output: +/Common/Sampled Common
Signal Input: Barrier Strip, Balanced
Communication Capabilities
Current Monitor: +/- 1V / 20A +/- 1%
Voltage Monitor: +/- 1V / 20V +/- 1%
Physical Characteristics
Chassis: All-aluminum construction designed for stand-alone benchtop or rack-mounted operation; with light pearl front panel and black chassis. The unit occupies six EIA 19-inch-wide units.
Weight: 128 lbs (57.9 kg),
AC Power: Three phase, 208 volts, 47-60 Hz, 20 amperes AC service.
Cooling: Forced air, 300 cfm.
Dimensions: 19 in. x 22.37 in. x 10.5 in. (48.3 cm x 56.8 cm x 26.7cm)
Copyright AE Techron, Inc. 2010 - Formerly Techron - MRI Mouse image courtesy of Aspect MRI - Report site problems to the webmaster.