7782 POWER AMPLIFIER
Short-Term, Burst or Continuous Power at Loads less than 2 ohms
Features
The 7782 power amplifier offers up to 150 Ap power, DC - 50 kHz bandwidth, and controlled-current or controlled-voltage modes of operation. The 7782 is the original member of the 7000 series, offered now as a remanufactured product; it offers a balance of great value, reliability and strong performance. The 7782 works best into loads of 2 ohms or less. For greater voltage or current, units can be combined in parallel or series.
Typically used as a gradient amplifier in small bore, high gain MRI systems of up to 150 Ap per axis and to reproduce waveforms found in EMC standards like MIL STD 1275, MIL STD 461, DO160, and ATIS-0600315.2007.
Optional "P" version offers precision control of output offset, DC drift and gain linearity.
- CONTROLLED VOLTAGE
- CONTROLLED CURRENT
- FREQUENCY DATA
- PHYSICAL CHARACTERISTICS
AC Specifications
Standard |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| open | 0 | 0 | 0 | 0 | 0 | ||||||
| 4 | 120 | 30 | 120 | 30 | 85 | 21 | 85 | 21 | 1799 | ||
| 2 | 120 | 60 | 115 | 58 | 85 | 42 | 81 | 41 | 3305 | ||
| 1 | 80 | 80 | 68 | 68 | 57 | 57 | 48 | 48 | 2311 | ||
| 0.5 | 46 | 92 | 44 | 88 | 33 | 65 | 31 | 62 | 1935 | ||
Optional High Current (HC) Version |
|||||||||||
| Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
| 40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
| Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
| 2 | 0 | 0 | 0 | 0 | 0 | ||||||
| 1 | 56 | 56 | 55 | 55 | 39 | 39 | 0 | 0 | 0 | ||
| 0.5 | 42 | 84 | 41 | 82 | 29 | 58 | 0 | 0 | 0 | ||
| 0.1 | 15 | 150 | |||||||||
Check back soon for updated product information



| 7782 DC Power Over Time Summary | |||
| Time in Minutes | Impedance | Volts | Amps |
| 2 | 1 | 50 | 50 |
| 2 | 0.5 | 30 | 60 |
| 1.5 | 0.27 | 19 | 75 |
| 5 | 1 | 40 | 40 |
| 5 | 2 | 84 | 42 |
| Continuous | 2 | 42 | 21 |
Indicators and Controls
Front Panel
LED Displays Indicate: Power, Standby, High AC Mains, High Temperature, Signal Overload and Faulty Output Stage.
Slide Switches for: Run/Standby, LED Indicator Reset
Back Panel
Signal Output: +/Common/Sampled Common
Signal Input: Barrier Strip, Balanced
Communication Capabilities
Current Monitor: +/- 1V / 20A +/- 1%
Voltage Monitor: +/- 1V / 20V +/- 1%
Physical Characteristics
Chassis: All-aluminum construction designed for stand-alone benchtop or rack-mounted operation; with light pearl front panel and black chassis. The unit occupies six EIA 19-inch-wide units.
Weight: 128 lbs (57.9 kg),
AC Power: Three phase, 208 volts, 47-60 Hz, 20 amperes AC service.
Cooling: Forced air, 300 cfm.
Dimensions: 19 in. x 22.37 in. x 10.5 in. (48.3 cm x 56.8 cm x 26.7cm)
Copyright AE Techron, Inc. 2010 - Formerly Techron - MRI Mouse image courtesy of Aspect MRI - Report site problems to the webmaster.