8101 POWER SUPPLY AMPLIFIER

8101 Power Supply Amplifier

 

Dual-Channel, AC-Coupled Power Supply Amplifier for Pulse or Continuous Duty Operation

8101 Frequency Response

Features

The 8101 power supply amplifier features an advanced switch-mode design that results in low noise and distortion, and high power density. It is configured as a dual-channel, AC-coupled, controlled voltage amplifier ideal for reactive loads. The 8101 can provide up to 16 Arms and 235 Vrms continuous output (bridge-mono mode). It offers a continuous, full-power frequency bandwidth of 10 Hz to 20 kHz.

The 8101 also features an integrated switching power supply that reduces weight and allows the unit to fit a standard 2U rack space. The 8101 operates from single-phase, 120-volt AC mains (230 VAC version available).

 

  • OUTPUT POWER
  • FREQUENCY DATA
  • POWER & THERMAL
  • PHYSICAL CHARACTERISTICS

Output Power

Dual Channel Mode - Both Channels Driven

Ohms

PEAK OUTPUT

RMS OUTPUT
40mSec Pulse,
30% Duty Cycle
5 Min,
100% Duty Cycle
1 Hr,
100% Duty Cycle
5 Min,
100% Duty Cycle
1 Hr,
100% Duty Cycle
Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Watts
open 167   167   167   118   118    
16.5 142 8.6 143 8.6 138 8 101 6.1 97.5 5.9 575
8 127 16 101 12.6 98 12 71.5 8.9 69.5 8.7 605
4 103 26 71 18 67 17 50 12.5 47.5 11.9 565
2 71 35 49 25 46 23 35 17.5 32.5 16.3 530
1 43 43 30 30 Not recommended 21.5 21.5 Not recommended

Bridge-Mono Mode

Ohms

PEAK OUTPUT

RMS OUTPUT
40mSec Pulse,
30% Duty Cycle
5 Min,
100% Duty Cycle
1 Hr,
100% Duty Cycle
5 Min,
100% Duty Cycle
1 Hr,
100% Duty Cycle
Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps Watts
open 335   335   335   235   235    
16 255 16 202 13 197 12 144 8.9 139 8.7 1209
8 206 26 141 18 134 17 100 12.5 95 11.9 1130
4 141 35 99 25 92 23 70 17.5 65 16.3 1059
2 86 44 59 30 Not recommended 42 21.0 Not recommended

    *not tested

8101 Crosstalk vs. Frequency

8101 Dampening Factor vs. Frequency

8101 DC Block

8101 LF Voltage Potential

 

Power Draw and Thermal Dissipation

Testing parameters:
  • Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
  • Typical line impedance used.
  • Measurements made with 120VAC mains. Data based on all channels driven.
  • Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
  • Line current figures for 100VAC units (not shown) are 1.2 times the line current figures of 120VAC units.
  • Power draw (”watts in”) of 100VAC units is the same as power draw of 120VAC units.
Program Load Rated Power Line Current 120 VAC Line Current 230 VAC Watts Thermal Dissipation
watts in watts out dissipated BTU/hr kcal/hr
At Idle:
Sleep Mode
40 0 40 137 34
1/8th Power Pink Noise:
Typical of program material just at clip.
8 ohms/CH, 16 ohms Bridge 1000x2 2000 6.6 3.3 546 256 290 988 249
4 ohms/CH, 8 ohms Bridge 1000x2 2000 7.0 3.5 563 255 307 1049 264
2 ohms/CH, 4 ohms Bridge 1000x2 2000 7.2 3.6 602 251 351 1198 302
70/100V/CH, 140/200V Bridge 1000x2 2000* 6.7 3.4 639 257 382 1304 329
1/3th Power Pink Noise:
Typical of program material with severe clipping.
8 ohms/CH, 16 ohms Bridge 1000x2 2000 11.3 5.6 980 676 304 1036 261
4 ohms/CH, 8 ohms Bridge 1000x2 2000 12.3 6.2 1064 672 392 1338 337
2 ohms/CH, 4 ohms Bridge 1000x2 2000 13.7 6.9 1190 705 485 1655 417
70/100V/CH, 140/200V Bridge 1000x2 2000 11.6 5.8 990 674 316 1080 272

 

8101 Front Panel Controls and Indicators

Front Panel Controls and Indicators

A. Fault Indicator: Red LED, one per channel, flashes when the amplifier output channel has stopped operating. Usually this means that the amplifier must be serviced.

B. Thermal Indicator: Red LED, one per channel, illuminates when the channel has shut down, or is very near shutting down, due to thermal stress or overload.

C. Ready Indicator: Green LED, one per channel, illuminates when the channel is initialized and ready to produce output. Indicator is off when the channel is set to standby mode via the System Architect or IQ Control Software packages.

D. Input Signal Indicator: Green LED, one per channel, illuminates when the channel’s input signal is above –40 dBu.

E. Output Signal Indicator, -20 dB: Green LED, one per channel, illuminates when the channel’s output signal is within 20 dB of clipping.

F. Output Signal Indicator, -10 dB: Green LED, one per channel, illuminates when the channel’s output signal is within 10 dB of clipping.

G. Clip Indicator: Red LED, one per channel, illuminates when the channel’s output signal reaches the onset of audible clipping. The Clip Indicator also will illuminate during Thermal Level Control (TLC) limiting or when the input compressor/limiter is protecting the amplifier from input overload.

H. Cooling Vents: Front-to-rear forced airflow.

I. Power Indicator: Blue LED indicates AC power has been applied and is within the safe operating range of the power supply. The LED will flash when the AC line voltage is approximately 15% above or 25% below the nominal rated value.

J. Data Indicator: Feature not implemented.

K. Bridge Mode Indicator: Yellow LED illuminates when the rear panel Mode Switch is set to the “Bridge” Position.

L. Power Switch: Push-on / push-off switch.

8101 Back Panel Controls and Connectors

Back Panel Controls and Connectors

M. Power Cord Connector: Standard 15 amp IEC inlet. A circuit breaker located near the IEC power inlet protects the amplifier from excessive AC current draw.

N. Reset Switch: Resets the circuit breaker that protects the power supply.

O. Ventilation Grille: Air flow is front to back. Do not block the ventilation grilles.

P. Input Panel: Input module includes two balanced 3-pin removable barrier connectors for Channel 1 and Channel 2 input. Also includes two 4-pin removable barrier connectors for Channel 1 and Channel 2 Voltage Monitors, and one 4-pin removable barrier connector for remote trigger to Standby Mode. Behind the input panel are the Input Sensitivity Switches (not shown). One 3-position switch per channel selects various sensitivity settings.

Q. Mode Switch: This two-position switch is used to select the amplifier’s mode of operation: Dual or Bridge Mono. Dual mode is used for 2-8 ohm loads. Bridge mode is used for 4-16 ohm loads.

R. Channel Level Controls: One 21-position detented rotary attenuator per channel, ranging from –100 dB to 0 dB gain.

S. High-Pass Filter: One 3-position switch per channel selects between OFF (FLAT), 35 Hz and 70 Hz 3-rd order filters.

T. Output Connectors: One four-pole touch-proof terminal strip. Accepts up to 10 AWG terminal forks.

Outupt Cover (not shown): This covers the output connectors, protecting users from the connectors’ potentially high voltage. This cover is required for Class 2 wiring installations.

Physical Characteristics

Chassis: The amplifier is designed for stand-alone or rack-mounted operation. The chassis is black aluminum with a powder-coat finish. The unit occupies two EIA 19-inch-wide units.

Weight: 27.0 lbs (12.3 kg).

Shipping Weight: 32.0 lbs (14.5 kg).

Required AC Mains (+15%, -25%): Single phase, 120VAC, 60 Hz, 20 Amp Service; 220-240 VAC, 50/60 Hz, 10 Amp model available.

Power Draw at Idle (120 VAC mains): 35 watts in Standby Mode.

Operating Temperature: 10°C to 50°C (50°F to 122°F), Maximum Output Power de-rated above 30°C (86°F).)

Humidity: 70% or less, non-condensing.

Cooling: Front-to-back airflow.

Dimensions (W x H x D): 19” x 3.5 “ x 14.25” (48.3 cm x 8.9 cm x 36.2 cm).

Copyright AE Techron, Inc. 2010-2012 - Formerly Techron - MRI Mouse image courtesy of Aspect MRI - Report site problems to the webmaster.