PRODUCT SUMMARY
8100 SERIES
8102 - The 8102 power supply amplifier features an advanced switch-mode design that results in low noise and distortion, and high power density. It is configured as a single-channel, DC-coupled, controlled voltage amplifier ideal for reactive loads. The 8102 can provide up to 16 Arms or 235 Vrms continuous output. It offers a continuous, full-power frequency bandwidth of DC to 5 kHz. The 8102 also features an integrated switching power supply that reduces weight and allows the unit to fit a standard 2U rack space. The 8102 operates from single-phase, 120-volt AC mains (230 VAC version available).
8101 - The 8101 power supply amplifier features an advanced switch-mode design that results in low noise and distortion, and high power density. It is configured as a dual-channel, AC-coupled, controlled voltage amplifier ideal for reactive loads. The 8101 can provide up to 16 Arms and 235 Vrms continuous output (bridge-mono mode). It offers a continuous, full-power frequency bandwidth of 10 Hz to 20 kHz. The 8101 also features an integrated switching power supply that reduces weight and allows the unit to fit a standard 2U rack space. The 8101 operates from single-phase, 120-volt AC mains (230 VAC version available).
RLY SERIES
7796RLY - The 77968RLY is a single channel, current source, power amplifier that can be used in combination with test sets or in conjunction with digital real time power system network simulators, (like RTDS). The 7796RLY amplifier can be combined to form three phase systems for testing of Protection Relays, it offers up to 200 Ap power, and DC - 10 kHz bandwidth.
7780RLY - The 7780RLY is a single channel, current source, power amplifier that can be used in combination with test sets or in conjunction with digital real time power system network simulators, (like RTDS). The 7780RLY amplifier can be combined to form three phase systems for testing of Protection Relays, it offers up to 150 Ap power, and DC - 10 kHz bandwidth.
7548RLY - The 7548RLY is a single channel, current source, power amplifier that can be used in combination with test sets or in conjunction with digital real time power system network simulators, (like RTDS). The 7548RLY amplifier can be combined to form three phase systems for testing of Protection Relays, it offers up to 100 Ap power, DC - 10 kHz bandwidth, all in a compact 5U size.
7000 SERIES
7796 - The 7796 power amplifier offers up to 200 Ap power, DC - 100 kHz bandwidth, and controlled-current or controlled-voltage modes of operation. The 7796 works best into loads of 2 ohms or less. For greater voltage or current (up to 800 Ap) units can be combined in parallel or series. Typically used as a gradient amplifier in small bore, high gain MRI systems of up to 200 Ap per axis and to reproduce waveforms found in EMC standards like MIL STD 1275, MIL STD 461, DO160, and ATIS-0600315.2007.
7782 - The 7782 power amplifier offers up to 150 Ap power, DC - 50 kHz bandwidth, and controlled-current or controlled-voltage modes of operation. The 7782 is the original member of the 7000 series, offered now as a remanufactured product; it offers a balance of great value, reliability and strong performance. The 7782 works best into loads of 2 ohms or less. For greater voltage or current, units can be combined in parallel or series. Typically used as a gradient amplifier in small bore, high gain MRI systems of up to 150 Ap per axis and to reproduce waveforms found in EMC standards like MIL STD 1275, MIL STD 461, DO160, and ATIS-0600315.2007.
7782HF - The 7782HF is an extended frequency verison of the 7782. The 7782HF is best suited for controlled voltage applications that require higher voltages between 50kHz - 100kHz. The 7782HF is ideal for situations like DO-160 testing that require high current from DC - 20kHz and DC - 150kHz power bandwidth.
7548 - The 7548 power amplifier offers up to 100 Ap power, DC - 100 kHz bandwidth, controlled current or controlled voltage modes of Operation, in a compact 5U size. The 7548 works best with loads of 2 ohms or more. For greater voltage (up to 750Vp) or current, units can be combined in series or parallel. Typically used as a gradient amplifier in small bore, high gain MRI systems of up to 100 Ap per axis and to reproduce waveforms found in EMC standards like MIL 704.
7224 - The 7224 power amplifier offers the power and features of larger industrial amplifiers in a new smaller 2U size that runs from single phase 120/230VAC. It features DC - 300 kHz bandwidth, controlled current or controlled voltage modes of operation and has a wide range of field configurable options. The 7224 is typically used to create waveforms found in EMC standards like CS2009, DO-160, MIL STD 461, and as a gradient amplifier for very small bore, high-gain MRI and NMR systems.
3000 SERIES
The AE Techron 3000 Series AC power amplifiers feature a contemporary, pulse-width modulation (Class D) design that features fast switching speeds, and low noise and drift specifications. The unit's unique, modeular design makes possible a wide range of custom configurations, including output isolation, output power up to 250 kVA, and increased voltage output.
3101 - Single-channel AC power amplifier - provides output of 10 kVA (100V / 100A)
3102 - Single-channel AC power amplifier - provides output of 20 kVA (100V / 200A)
3103 - Single-channel AC power amplifier - provides output of 30 kVA (100V / 300A)
3303 - Three-channel AC power amplifier - provides output of 30 kVA (100V / 300A)
3306 - Three-channel AC power amplifier - provides output of 60 kVA (100V / 600A)
3309 - Three-channel AC power amplifier - provides output of 90 kVA (100V / 900A)
Copyright AE Techron, Inc. 2010-2012 - Formerly Techron - MRI Mouse image courtesy of Aspect MRI - Report site problems to the webmaster.