7226: Up to 50 Ap/158 Vp, DC to 600 kHz, Single-Phase

7226
Single-phase, 2U, industrial amplifier
- Up to 2X the long-term power of the 7224 at frequencies above 40 kHz
- Field-selectable controlled-voltage or controlled-current operation
- Can be switched between rail supply modes and voltages to optimize for various load impedances
- Protection circuits guard against over/under voltage, over current, over temperature, and circulating ground currents
Key Performance Capabilities:
- Up to 900 watts RMS power output
- Small signal response up to 600 kHz
- 90 V/µs slew rate
- Can be used to create series or parallel systems for up to 3 times the voltage or 4 times the current output
The 7226 is a 4-quadrant, 900VA, DC-enabled power amplifier that provides exceptional versatility and value. It features DC - 600 kHz small-signal bandwidth and improved long-term power performance at frequencies above 40 kHz.
The 7226 can be field-configured to run well into loads from 100 ohms to as low as 0.5 ohms. Even with its small bench top size, the 7226 is able to produce as much as 50 amps of current and as much as 158 volts, providing serious power for a wide range of applications and experiments. With its 90V/µS slew rate, it is able to accurately reproduce wave forms from DC to above 600 kHz, making it a great choice for high-speed control applications. With its ability to operate in either Controlled-Voltage or Controlled-Current modes, it can be used in Small Bore MRI and NMR systems, testing of switch-mode power supply components, and driving Helmholtz coils.
Output
AC Output
Note: Testing performed into resistive loads as specified. Performance reported is typical into the specified load up to 20 kHz frequency levels. Performance may be affected when operating into highly reactive loads or above 20 kHz, reducing maximum voltage, current and power output. *Testing not performed. **Maximum 45 minutes of continuous operation.
High-voltage Mode
Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
16 | 158 | 9.8 | 158 | 9.8 | 158 | 9.8 | 112 | 6.9 | 112 | 6.9 | 773 |
8 | 154 | 19 | 136 | 16 | 120** | 15** | 96 | 11.5 | 85** | 10.6** | 900** |
4 | 124 | 31 | 108 | 25.7 | 61 | 14.5 | 76 | 18.2 | 43 | 10.3 | 443 |
2 | 98 | 49 | * | * | * | * | * | * | * | * | * |
Mid-level Mode
Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
4 | 72 | 18 | 69 | 16.4 | 69 | 16.4 | 49 | 12 | 49 | 12 | 568 |
2 | 61 | 30 | 57 | 26.2 | 57 | 26.2 | 40 | 18.5 | 40 | 18.5 | 740 |
1 | 47 | 47 | 43 | 39.6 | 21 | 21 | 30 | 28 | 15 | 14.8 | 222 |
0.5 | 26 | 52 | * | * | * | * | * | * | * | * | * |
High-current Mode
Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
1 | * | * | 29 | 29 | 29 | 29 | 21 | 21 | 20.5 | 20.5 | 420 |
0.75 | * | * | 26 | 34 | 26 | 34 | 18 | 24 | 18 | 24 | 432 |
0.5 | * | * | 22.7 | 45 | 22.7 | 45 | 16 | 32 | 16 | 32 | 512 |
DC Output
Note: Testing performed in high-current mode.
OUTPUT (Amperes) |
|||
Volts DC | 100 mS Surge |
10 Minutes, 100% Duty Cycle |
1 Hour, 100% Duty Cycle |
48.0 | 40 | 12 | 12 |
24.0 | 45 | 26 | 20 |
13.5 | 50 | 20 | 16 |

Performance
Frequency Data


Front & Back


Specifications
Performance
Testing was done at 100 Hz. Continuous DC power levels are lower. See DC Specifications chart for test conditions.
Frequency Response,
DC - 300 kHz (1 watt): +1.0 to -1.5 dB
Slew Rate: 90 V/µSec
Residual Noise:
10 Hz to 300 kHz: 950 µV (0.95 mV)
10 Hz to 80 kHz: 300 µV (0.3 mV)
Signal-to-Noise Ratio:
10 Hz - 30 kHz: –113 dB
10 Hz - 80 kHz: –106.6 dB
10 Hz - 500 kHz: –99.9 dB
Unit to Unit Phase Error: ±0.1 degrees at 60 Hz
THD (DC - 30 kHz): less than 0.1%
DC Offset: Less than ±400 µV
DC Drift: Less than ±200 µV (after 20 minutes of operation)
Output Impedance:
5.3 mOhm in Series with 0.95 µH
Phase Response (10 Hz - 10 kHz) :
±5 degrees plus 600 nsec
propagation delay
Input Characteristics
Balanced with ground: Three terminal barrier block connector, 20k ohm
differential
Unbalanced: BNC connector, 10k ohm single ended.
Gain, Voltage Mode: 20 volts/volt; Current Mode: 5 amperes/volt
Gain Linearity (over input signal, from 0.2V to 5V): 0.02% (DC); 0.05% (AC)
Max Input Voltage:
±10V, balanced or unbalanced
Common Mode Rejection: -58 dB with 5V input
Status Display, Control, I/O
Front Panel LED Displays indicate: Ready, Standby, Fault, Over Temp, Over Voltage, Overload
Soft Touch Switches for: Run, Stop, Reset
Gain Control, when enabled: Voltage gain adjustable from 20 to 0
On/Off Breaker
Back Panel Power Connection: 25 Amp IEC (with retention latch)
Signal Output: Three-position terminal strip (OUTPUT/COM/CHASSIS GROUND)
Signal Input: User Selectable BNC or Barrier Strip, Balanced or Unbalanced
Communication Capabilities
Current Monitor: 5A/V ± 1%; 2.5A/V ± 1% (differential configuration)
Reporting: System Fault, Over Temp, Over Voltage, Over Load
Remote Control via Interlock Connector: Blanking control, Force to Standby, Reset after a fault
Protection
Over/Under Voltage:
± 10% from specified supply voltage amplifier is forced to Standby
Over Current:
Breaker protection on both main power and low voltage supplies
Over Temperature:
Separate Output transistor, heat sink, and transformer temperature monitoring and protection
Physical Characteristics
Chassis:
The Amplifier is designed for stand- alone or rack-mounted operation. The Chassis is black aluminum with a powder coat finish. The unit occupies two EIA 19-inch-wide units.
Weight: 41 lbs (18.6 kg), Shipping 51 lbs (23.2 kg)
AC Power: Single phase, 120 VAC, 60 Hz, 20 Amp service; (220-240 VAC, 50-60 Hz, 10 Amp service model available)
Operating Temperature:
10°C to 50°C (50°F to 122°F), maximum output Power de-rated above 30°C (86°F).
Humidity:
70% or less, non-condensing
Cooling: Forced air cooling from front to back through removable filters.
Airflow:
180CFM
Dimensions: 19” x 22.75” x 3.5” (48.3 cm x 57.8 cm x 8.9 cm)
Downloads
7226 Datasheet
Complete technical specifications
7224/7226 Operator's Manual
For 7224 and 7226 amplifiers
Multiamp Configuration Guide
For 7224, 7226, 7548, 7794 and 7796 amplifiers
SIM Pinouts and Functions
For 7224, 7226, 7548, 7794 and 7796 amplifiers
Recommended Accessories
Want to discuss a product or application?
Our knowledgeable sales and support staff can help find the right system for your needs.
We're the audio-bandwidth experts.