7212: Up to 113V RMS Potential at up to 4A
The 7212 is a four-quadrant, 0.44 kVA, DC-enabled power amplifier that was created to meet the exacting requirements of the power utility industry. It features a DC to 250 kHz bandwidth, low noise floor, fast slew rate and a 113 VRMS potential. The 7212 can be combined to form a 3-phase Y voltage source, and has a wide range of field-configurable options.
A single 7212 can output a 40 ms pulse with up to 30 amperes peak current. In continuous operation, a 7212 can provide 440 watts RMS of output power. If more voltage is needed, up to four amplifiers can be combined in series and operate as a single system.
The 7212 can operate in either voltage or current mode and can be configured by the customer for high-voltage/low-current, medium voltage and current, or low- voltage/high-current applications. It provides very low noise and fast slew rates, and can safely drive a wide range of resistive or inductive loads.
7212
For Power Grid Simulation
- DC – 250 kHz bandwidth design minimizes phase shift of system output when reproducing the most rapid fault events
- Can be field-configured for high-voltage/lowcurrent, medium voltage and current, or low-voltage/high-current applications
- Four-quadrant operation
- User-selectable controlled-voltage or controlled-current modes of operation
- Protection circuitry protects from input overloads, improper output connection (including shorted and improper loads), over-temperature, over-current, and supply voltages that are too high or low
Key Performance Capabilities:
- Up to 113V RMS at up to 4A
- Pulsed output up to 30 Ap
- 430 watts RMS continuous output
- Low noise floor of only 300 µV
- Fast, 50 V/µs slew rate
- System output of over 1,700 watts is possible with multiple, interconnected amplifiers
Output
AC Output
Note: Testing performed into resistive loads as specified. Performance reported is typical into the specified load up to 20 kHz frequency levels. Performance may be affected when operating into highly reactive loads or above 20 kHz, reducing maximum voltage, current and power output. *Testing not performed.
High-voltage Mode
Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
32 | 166 | 5.1 | 161 | 5 | 161 | 5 | 113 | 3.6 | 113 | 3.6 | 407 |
16 | 147 | 9 | 146 | 9 | 120 | 7.4 | 102 | 6.3 | 85 | 5.2 | 442 |
8 | 123 | 15 | 98 | 12 | 68 | 8.5 | 69 | 8.5 | 48 | 6 | 288 |
4 | 95 | 23.1 | * | * | * | * | * | * | * | * | * |
Mid-level Mode
Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
8 | 72 | 8.8 | 71 | 8.8 | 71 | 8.8 | 51 | 6.2 | 51 | 6.2 | 313 |
4 | 62 | 14.8 | 60 | 14.8 | 59 | 14.6 | 42 | 10.5 | 42 | 10.3 | 432 |
2 | 48 | 22.7 | 42 | 21.2 | 30 | 14.1 | 30 | 15 | 20 | 10 | 200 |
1 | 32 | 30 | * | * | * | * | * | * | * | * | * |
High-current Mode
Ohms | PEAK OUTPUT |
RMS OUTPUT |
|||||||||
40mSec Pulse, 30% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
5 Min, 100% Duty Cycle |
1 Hr, 100% Duty Cycle |
|||||||
Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Volts | Amps | Watts | |
2 | 30 | 14.9 | 30 | 14.9 | 30 | 14.9 | 21 | 10.5 | 21 | 10.5 | 225 |
1.5 | 27 | 17.6 | 27 | 17.7 | 27 | 17.7 | 19 | 12.5 | 19 | 12.4 | 236 |
1 | 24 | 22.6 | 24 | 22.6 | 24 | 22.6 | 17 | 16 | 17 | 16 | 272 |
Performance
Frequency Data
Front & Back
Specifications
Performance
AC testing was performed at 1 kHz.
Small Signal Frequency Response,
DC - 100 kHz (1 watt): +0.0 to -3.0 dB
8-Ohm Power Response (continuous duty):
DC to 60 kHz: ± 140 Vpk
DC to 100 kHz: ± 50 Vpk
Slew Rate: 50 V/µSec
Residual Noise:
10 Hz to 300 kHz: 950 µV (0.95 mV)
10 Hz to 80 kHz: 300 µV (0.3 mV)
Signal-to-Noise Ratio:
10 Hz - 30 kHz: –113 dB
10 Hz - 80 kHz: –106.6 dB
Unit to Unit Phase Error: ±0.1 degrees at 60 Hz
THD (DC - 30 kHz): less than 0.1%
Output Offset: Less than ±5 mV, field adjustable to less than 1 mV
DC Drift: ±1.5mV
Output Impedance:
5.3 mOhm in Series with 0.95 µH
Phase Response (10 Hz - 10 kHz) :
±5 degrees plus 560 nsec
propagation delay
Input Characteristics
Balanced with ground: Three terminal barrier block connector, 20k ohm
differential
Unbalanced: BNC connector, 10k ohm single ended.
Gain (variable or fixed),
Voltage Mode: 20 volts/volt
Current Mode: 5 amperes/volt
Max Input Voltage:
±10V, balanced or unbalanced
Input Impedance: 20k ohm differential
Common Mode Rejection: -58 dB with 5V input
Status Display, Control, I/O
Front Panel LED Displays indicate: Ready, Standby, Fault, Over Temp, Over Voltage, Overload
Soft Touch Switches for: Run, Stop, Reset
Gain Control, when enabled: Voltage gain adjustable from 20 to 0
On/Off Breaker
Back Panel Power Connection: 25 Amp IEC (with retention latch)
Signal Output: Three-position terminal strip (OUTPUT/COM/CHASSIS GROUND)
Signal Input: User Selectable BNC or Barrier Strip, Balanced or Unbalanced
Communication Capabilities
Current Monitor: 5A/V ± 1%; 2.5A/V ± 1% (differential configuration)
Reporting: System Fault, Over Temp, Over Voltage, Over Load
Remote Control via Interlock Connector: Force to Standby, Reset after a fault
Protection
Over/Under Voltage:
± 10% from specified supply voltage amplifier is forced to Standby
Over Current:
Breaker protection on both main power and low voltage supplies
Over Temperature:
Separate Output transistor, heat sink, and transformer temperature monitoring and protection
Physical Characteristics
Chassis:
The Amplifier is designed for stand- alone or rack-mounted operation. The Chassis is black aluminum with a powder coat finish. The unit occupies two EIA 19-inch-wide units.
Weight: 35 lbs (15.9 kg), Shipping 45 lbs (20.4 kg)
AC Power: Single phase, 120 VAC, 60 Hz, 10 Amp service; (220-240 VAC, 50-60 Hz, 5 Amp service model available)
Operating Temperature:
10°C to 50°C (50°F to 122°F), maximum output Power de-rated above 30°C (86°F).
Humidity:
70% or less, non-condensing
Cooling: Forced air cooling from front to back through removable filters.
Airflow:
180CFM
Dimensions (HxWxD): 3.5” x 19” x 22.75” (8.9 cm x 48.3 cm x 57.8 cm)
Downloads
Recommended Accessories
Want to discuss a product or application?
Our knowledgeable sales and support staff can help find the right system for your needs.
We're the audio-bandwidth experts.